Olympus AU400 Automated Chemistry Analyzer

Specifications

400 photometric tests per hour 
Racks with 10 samples each Bar and total 80 samples continuous loading 
Refrigerated 4C-12C

Condition: Excellent. 6 months warranty. For more information, please email us at sales@bastmed.com or check directly http://www.bastmed.com

There are total accessories are coming with the intstrument are below,

AU-640 accessories: It should come with a computer cart, , white racks, 1 blue rack, 1 green rack, 1 yellow racks, 1 orange rack and 1 red rack. In addition all probes, mix bars, reagent trays and syringes should still be on the instrument.

Simultaneously processed analytes
Up to 38 photometric tests + 3 ISE
Throughput
400 photometric tests / hour; maximum of 800 with ISE
Sample feeder
Racks with 10 samples each (bar-codes on primary tubes and on racks); capacity of 80 samples; continuous loading
Sample tubes
In primary and secondary tubes; diameter from 11.5 to 16 mm; height from 55 to 102 mm
STAT samples
Up to 22 positions for STAT samples, bar-coded primary tubes
Sample volume
2 – 50 µl in 1 µl steps (1– 50 µl for repeats)
Reagent supply
Refrigerated (4 °C – 12 °C); 76 positions for R1/ R2
Reagent volume
1. reagent: 25 – 300 µl; 2. reagent: 25 – 300 µl; (in 1 µl steps)
Total reaction volume
150– 550 µl
Reaction cuvette
Quartz cuvettes
Reaction time
Up to 8 minutes, 40 seconds
Reaction temperature
37 °C
Mixing method
With rotating paddles after dispensing sample and reagent
Photometry system
Direct assay through the reaction cuvette (0 – 2.5 OD) mono-, bichromatic measurements possible
Wave length
13 different wave lengths between 340 – 800 nm
Cuvette cleaning
Comprehensive cleaning with detergents
Calibration
Linear and non linear (linear interpolation), refrigerated calibrator positions
Data processing
Calculated parameters, blank value correction and correlation. Definition of normal value range, measuring range, pathological values and repeats. Quality controls, printout of abnormal values, pending sample work list and repeat run sample list
Test requisition
Individual and profile test requisition via on-line, mouse, function keys or optional touch screen
Safety
Clot detection and crash prevention for sample and reagent dispenser
On-line
Full uni- and bidirectional communication possible
Software
Windows-NT®

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s