Agilent 6120 Quadrupole LCMS System

For more details please email us at sales@bastmed.com or http://www.bastmed.com

Image

The front end LC is optional and can be added to the system.

Agilent 6120 MSD
Edwards Vacuum Pump
Computer with the ChemStation

Optional:

Agilent 1200 Series G13798 degasser
Agilent 1200 Series G1377A Micro WPS
Agilent 1200 Series G1330B FC / ALS Therm
Agilent 1200 Series pump G1376A Cap
Plateau

Details
The 6120 Series LC / MS System Agilent quadrupole is in excellent condition. The Agilent 6100 Series Quadrupole LC / MS systems (LC MS / LCMS / MSD LC / LC-MS) are the result of several generations of refinement quadrupole LC / MS. They offer unparalleled performance combined with proven durability and ease of use, and now have a footprint barely half the size of previous models. The 6110 and 6120 are outstanding for a wide range of applications and their reasonable price puts the power of mass spectrometry to the scope of other laboratories than ever. The four models in the Agilent 6100 Series integrate seamlessly with Agilent 1200 and 1100 Series LC modules. You control all the modules with the data system of the Agilent ChemStation, offering unprecedented levels of automation for reliable unattended operation and increased productivity. The 6100 series systems are the cornerstone of comprehensive LC / MS solutions. They are suitable for applications as diverse as identity confirmationfor combinatorial libraries of drug candidates through the quantification of insecticides and herbicides in water samples.
The system is configurable with the choice of ionization:

electrospray ionization (ESI) source to analyze large and small polar molecules.
Source chemical atmospheric pressure ionization (APCI) for analyzing a series of less polar and nonpolar molecules.
Multimode Source for Simultaneous ESI and APCI ionization, providing maximum coverage and a higher response rate.

The price may vary depending on the choice of the ion source.
System specifications:

Mass range m / z 10-1500
accurate mass: 0.13 ± u in the range of calibrated mass scanning mode of
stability of the mass axis: mass of the drift does not exceed the absolute value of more or u ± 0.1 ± 100 ppm from the mass measured over a period of 12 hours at a constant temperature ± 3 degrees centigrade
Scan Speed: 2500 u / s
SIM sensitivity: • ESI 400 ft / min or APCI to 1000 ft / min • monitoring of selected m / z 609.3 ion • 10 pg reserpine positive ions, 100:1 RMS (peak to 8:01 p.m. peak)
Scan Sensitivity: • ESI 400 ft / min or APCI to 1000 ft / min • scan range m / z 100-650 • Scan speed 2500 U / s • Extracted ion at m / z 609.3 • positive ionization
Acquisition of multiple signals: Ability to cycle through the four different acquisition modes on a basic scanning by a single pass.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s